{"id":550,"date":"2021-10-08T11:36:50","date_gmt":"2021-10-08T14:36:50","guid":{"rendered":"http:\/\/ecolumeweb.com.br\/?post_type=product&#038;p=550"},"modified":"2021-10-13T10:32:09","modified_gmt":"2021-10-13T13:32:09","slug":"contactores","status":"publish","type":"product","link":"http:\/\/ecolumeweb.com.br\/?product=contactores","title":{"rendered":"Contactores"},"content":{"rendered":"<table style=\"height: 407px;\" width=\"1293\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"302\">Tipo<\/td>\n<td style=\"text-align: center;\" width=\"103\">CJX1B-9<\/td>\n<td style=\"text-align: center;\" width=\"73\">CJX1B-12<\/td>\n<td style=\"text-align: center;\" width=\"86\">CJX1B-16<\/td>\n<td style=\"text-align: center;\" width=\"104\">CJX1B-22<\/td>\n<td style=\"text-align: center;\" width=\"114\">CJX1B-32<\/td>\n<td style=\"text-align: center;\" width=\"116\">CJX1B-38<\/td>\n<td style=\"text-align: center;\" width=\"100\">CJX1B-45<\/td>\n<td style=\"text-align: center;\" width=\"104\">CJX1B-63<\/td>\n<td style=\"text-align: center;\" width=\"107\">CJX1B-75<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Voltagem Nominal Isolante V<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" rowspan=\"2\">Corrente Operacional Nominal A<\/td>\n<td style=\"text-align: center;\">AC-3 380V<\/td>\n<td style=\"text-align: center;\">9<\/td>\n<td style=\"text-align: center;\">12<\/td>\n<td style=\"text-align: center;\">16<\/td>\n<td style=\"text-align: center;\">22<\/td>\n<td style=\"text-align: center;\">32<\/td>\n<td style=\"text-align: center;\">38<\/td>\n<td style=\"text-align: center;\">45<\/td>\n<td style=\"text-align: center;\">63<\/td>\n<td style=\"text-align: center;\">75<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">AC-4 380V<\/td>\n<td style=\"text-align: center;\">3,3<\/td>\n<td style=\"text-align: center;\">4,3<\/td>\n<td style=\"text-align: center;\">7,7<\/td>\n<td style=\"text-align: center;\">8,5<\/td>\n<td style=\"text-align: center;\">15,6<\/td>\n<td style=\"text-align: center;\">18,5<\/td>\n<td style=\"text-align: center;\">24<\/td>\n<td style=\"text-align: center;\">28<\/td>\n<td style=\"text-align: center;\">34<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" rowspan=\"3\" width=\"214\">Alta Tens\u00e3o Controlada KW da Maioria dos Motors com Classifica\u00e7\u00e3o uso AC-3<\/td>\n<td style=\"text-align: center;\">220V<\/td>\n<td style=\"text-align: center;\">2,2<\/td>\n<td style=\"text-align: center;\">3<\/td>\n<td style=\"text-align: center;\">4<\/td>\n<td style=\"text-align: center;\">5,5<\/td>\n<td style=\"text-align: center;\">8,5<\/td>\n<td style=\"text-align: center;\">11<\/td>\n<td style=\"text-align: center;\">15<\/td>\n<td style=\"text-align: center;\">18,5<\/td>\n<td style=\"text-align: center;\">22<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">380V<\/td>\n<td style=\"text-align: center;\">4<\/td>\n<td style=\"text-align: center;\">5,5<\/td>\n<td style=\"text-align: center;\">7,5<\/td>\n<td style=\"text-align: center;\">11<\/td>\n<td style=\"text-align: center;\">15<\/td>\n<td style=\"text-align: center;\">18,5<\/td>\n<td style=\"text-align: center;\">22<\/td>\n<td style=\"text-align: center;\">30<\/td>\n<td style=\"text-align: center;\">37<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">680V<\/td>\n<td style=\"text-align: center;\">5,5<\/td>\n<td style=\"text-align: center;\">7,5<\/td>\n<td style=\"text-align: center;\">11<\/td>\n<td style=\"text-align: center;\">11<\/td>\n<td style=\"text-align: center;\">15<\/td>\n<td style=\"text-align: center;\">15<\/td>\n<td style=\"text-align: center;\">39<\/td>\n<td style=\"text-align: center;\">55<\/td>\n<td style=\"text-align: center;\">67<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"2\">Corrente de Aquecimento A<\/td>\n<td style=\"text-align: center;\">20<\/td>\n<td style=\"text-align: center;\">20<\/td>\n<td style=\"text-align: center;\">30<\/td>\n<td style=\"text-align: center;\">30<\/td>\n<td style=\"text-align: center;\">55<\/td>\n<td style=\"text-align: center;\">55<\/td>\n<td style=\"text-align: center;\">80<\/td>\n<td style=\"text-align: center;\">90<\/td>\n<td style=\"text-align: center;\">100<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"214\">Frequ\u00eancia Operacional\u00a0\u00a0\u00a0 Tempo\/h<\/td>\n<td style=\"text-align: center;\">AC-3<\/td>\n<td style=\"text-align: center;\">1000<\/td>\n<td style=\"text-align: center;\">1000<\/td>\n<td style=\"text-align: center;\">750<\/td>\n<td style=\"text-align: center;\">750<\/td>\n<td style=\"text-align: center;\">600<\/td>\n<td style=\"text-align: center;\">600<\/td>\n<td style=\"text-align: center;\">1200<\/td>\n<td style=\"text-align: center;\">1000<\/td>\n<td style=\"text-align: center;\">1000<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">AC-4<\/td>\n<td style=\"text-align: center;\">250<\/td>\n<td style=\"text-align: center;\">250<\/td>\n<td style=\"text-align: center;\">250<\/td>\n<td style=\"text-align: center;\">250<\/td>\n<td style=\"text-align: center;\">250<\/td>\n<td style=\"text-align: center;\">200<\/td>\n<td style=\"text-align: center;\">400<\/td>\n<td style=\"text-align: center;\">300<\/td>\n<td style=\"text-align: center;\">300<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Fator de Carga AC-3<\/td>\n<td style=\"text-align: center;\" colspan=\"10\">40%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>O Contator CA s\u00e9rie CJX1B \u00e9 usado principalmente em circuitos de CA de 50Hz\/60Hz com tens\u00e3o nominal de 1000V ou corrente nominal de 475A enquanto a tens\u00e3o nominal operacional \u00e9 380V sob tipo de uso AC-3. \u00c9 utilizado para realizar e interromper remotamente corrente e controle de motor CA.<\/p>\n<p>Aqueles que controlam os motores CA s\u00e3o in\u00edcio, parada e giro. Isto e a sobrecarga t\u00e9rmica apropriada\u00a0 liberam o starter eletromagn\u00e9tico composto para proteger contra eventual sobrecarga de circuito na opera\u00e7\u00e3o.<\/p>\n<p>Os produtos cumpem a norma IEC60947-4-1<\/p>\n","protected":false},"featured_media":837,"template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"off","neve_meta_content_width":100,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","_themeisle_gutenberg_block_has_review":false,"_ti_tpc_template_sync":false,"_ti_tpc_template_id":""},"product_cat":[48,46],"product_tag":[],"class_list":["post-550","product","type-product","status-publish","has-post-thumbnail","product_cat-contactores","product_cat-materiais-eletricos","first","instock","shipping-taxable","purchasable","product-type-variable","has-default-attributes"],"_links":{"self":[{"href":"http:\/\/ecolumeweb.com.br\/index.php?rest_route=\/wp\/v2\/product\/550","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/ecolumeweb.com.br\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"http:\/\/ecolumeweb.com.br\/index.php?rest_route=\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/ecolumeweb.com.br\/index.php?rest_route=\/wp\/v2\/media\/837"}],"wp:attachment":[{"href":"http:\/\/ecolumeweb.com.br\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=550"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"http:\/\/ecolumeweb.com.br\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=550"},{"taxonomy":"product_tag","embeddable":true,"href":"http:\/\/ecolumeweb.com.br\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=550"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}